Evaluation of protective efficiency of filter respirators in selection and operation
Serhii Cheberiachko
Dnipro University of Technology
http://orcid.org/0000-0001-5866-4393
Oleg Deryugin
Dnipro University of Technology
http://orcid.org/0000-0002-2456-7664
Olena Sharovatova
National University of Civil Defence of Ukraine
http://orcid.org/0000-0002-2736-2189
Tatiana Lutsenko
National University of Civil Defence of Ukraine
http://orcid.org/0000-0001-7373-4548
Mykola Naumov
Dnipro University of Technology
http://orcid.org/0000-0002-9748-2506
DOI: https://doi.org/10.52363/2524-0226-2021-34-3
Keywords: ignition of materials, gaseous indoor environment, amplitude instantaneous spectrum, phase instantaneous spectrum
Аnnotation
The influence of errors and inconsistencies on the protective effectiveness of filter respirators during the process of their selection and operation, which is due to the need to assess occupational risks in the selection of filter respirators. The method of functional resonance analysis of the study was used to model the development of different scenarios through the description of the functions of the process of selection and operation of respiratory protection, which will lead to deterioration of workers' protection based on the time of operation, availability of necessary resources and appropriate level of control. The main functions in the selection and operation of personal respiratory protection, which depend on the analysis of working conditions, justification for the choice of personal respiratory protection, checking the adequacy and features of the operation of filter respirators based on input data, operating time of possible prerequisites, required resources and appropriate level control. To describe the variability of functions, it is proposed to consider four scenarios based on their timely and accurate implementation, which allowed to present possible errors in the selection and operation of filter respirators and their consequences for effective protection of the worker given the development of several possible positive and negative results. implementation. Recommendations have been developed to reduce errors in the selection and operation of filter respirators, which is extremely important and necessary to maintain the appropriate level of protection of users throughout the specified period of operation by strengthening control over their protective properties at each stage of use.
References
- Ankur, A., Sheetal, A., Poonam, M. Difficulties encountered while using PPE Kits and how to overcome them: An Indian perspective, 2020, Nov, 12(11): e11652. doi: 10.7759/cureus.11652
- Srijit, D., Sakthiswary, R. Personal protective equipment (PPE) and its use in COVID-19: important facts, 2020 May 28: 1–2. doi: 10.1007/s12262-020-02411-8
- Occupational risk perception and the use of personal protective equipment (PPE): A study among informal automobile artisans in Osun state, Nigeria. January 2021. SAGE Open 11(1):215824402199458. doi:10.1177/2158244021994585
- Syed, U., Faine, C., Sheharyar, K., Erum, C. at al. Strategies for rational use of personal protective equipment (PPE) among healthcare providers during the COVID-19 crisis. , 2020 May, 12(5): e8248. doi: 10.7759/cureus.8248
- Tinoco, H., Lima, G., Sant’Anna, A., Gomes, C. at al. Risk perception in the use of personal protective equipment against noise-induced hearing loss. Gestão Produção, 2019, 26(1), e1611. doi: 10.1590/0104-530X1611-19
- Schau, H., Mehlem, M. Risk analysis and guidelines for selecting PPE against the thermal hazards of electric fault arcs. ICOLIM 2011, 10th International conference on live maintenance; May 31th – June 2nd 2011, Zagreb, Croatia. Available online: urn:nbn:de:gbv:ilm1-2012200088
- Critical review of the role of PPE in the prevention of risks related toagricultural pesticide use / A. Garrigoua, C. Laurentb, A. Berthetc, C. Colosiod, N. Jase, V. Daubas-Letourneuxf, J.-M. Jackson Filhog, J.-N. Jouzelh, O. Samueli, I. Baldia, P. Lebaillyj, L. Galeya, F. Goutillea, N. Judona. Safety Science. Volume 123, March 2020, 104527. doi: 10.1016/j.ssci.2019.104527
- Cheberiachko, S., Deryugin, О., Mirnenko, V., Borodina, N. Selection of effective filter respirators. Challenges and opportunities. Journal of Scientific Papers «Social Development and Security», 2020, 10, 4, 23–41. doi: 10.33445/sds.2020.10.4.3
- Hussein, S., Nadeau, S. Proposal for a predictive performance assessment model in complex sociotechnical systems combining fuzzy logic and the functional resonance analysis method (FRAM). American Journal of Industrial and Business Management, 2019, 9, 6. 1345–1375. doi: 10.4236/ajibm.2019.96089
- Patriarca, R., Di Gravio, G., Costantino, F. A Monte Carlo evolution of the functional resonance analysis method (FRAM) to assess performance variability in complex systems. Safety Science, 2017, 91, 49–60. doi: 10.1016/j.ssci.2016.07.016
- Frost, B., Mo, J. System hazard analysis of a complex socio-technical system: the functional resonance analysis method in hazard identification. Australian system safety conference, Melbourne Australia, 28-30 May 2014, Retrieved from: http://surl.li/audtz
- Patriarca, R., Del Pinto, G., Di Gravio, G., Costantino, F. FRAM for systemic accident analysis: a matrix representation of functional resonance. International journal of reliability, quality and safety engineering, 25, 01, 2018. 1850001. doi: 10.1142/S0218539318500018
- Han, D., Chung, S., Kim, J., Cho, Y. at al. A study on selecting personal protective equipment for listed hazardous chemicals: analysis of hazard ranks and workplace exposure risks. J Environ health sci, 42 (6), 2016, 419–429. doi: 10.5668/JEHS.2016.42.6.419
- Han, D. Selection guide to wearing respirators according to work situations and on-site applicability. Safety and health at work, 2021. doi: 10.1016/j.shaw.2021.07.011