Study of the influence of building material on the structure of buildings on the development of internal fire

 

Dmytro Dubinin

National University of Civil Defence of Ukraine

https://orcid.org/0000-0001-8948-5240

 

Andrii Lisniak

National University of Civil Defence of Ukraine

https://orcid.org/0000-0001-5526-1513

 

Serhii Shevchenko

National University of Civil Defence of Ukraine

https://orcid.org/0000-0002-6740-9252

 

Yevhen Kryvoruchko

National University of Civil Defence of Ukraine

https://orcid.org/0000-0001-7332-9593

 

Yuri Gaponenko

National University of Civil Defence of Ukraine

https://orcid.org/0000-0003-0854-5710

 

DOI: https://doi.org/10.52363/2524-0226-2022-35-13

 

Keywords: internal fire, temperature, time of thermal penetration, coefficient of thermal conductivity, rate of energy release

 

Аnnotation

Researches of influence of building material of a design of a building on development of an internal fire are carried out. Brick was used as a building material in the first variant, concrete in the second variant, aerated concrete in the third variant, and expanded clay concrete in the fourth variant. Taking into account the proposed method and conditions of internal fire development, graphical dependences of thermal conductivity coefficient and fire development time are constructed, according to which it is established that when using concrete as a building material – maximum thermal conductivity coefficient – 0,0823 W/(m2·K) for 5 min internal fire, and 0.0412 W/(m2·K) for 20 min, and from aerated concrete minimum – 0,0153 W/(m2·K) for 5 min and 0.0076 W/(m2·K) for 20 min. At the same time, the time of thermal penetration through the wall according to the first option is 81,15 minutes, according to the second option – 70,0 minutes, the third option – 148,8 minutes, the fourth option – 80,0 minutes. There are also graphical dependences on the increase in wall temperature on the rate of energy release in four variants during the development of internal fire for 5 minutes and 20 minutes. It is established that the minimum value of the temperature of the concrete wall, depending on the rate of energy release for 5 minutes of fire development is about 208 ºC, and for 20 minutes – 260 ºC. The maximum value of the temperature of the wall of aerated concrete and expanded clay concrete for 5 minutes of fire development is about 350 ºC, and for 20 minutes – 440 ºC. The results of the research allow to increase the level of operational readiness of the personnel of fire and rescue units during the operational actions to extinguish internal fires, as well as in determining the fire hazard of building materials.

 

References

  1. Nakaz МVS № 340. (2018). Pro zatverdzhennja Statutu dij organiv upravlinnja ta pidrozdiliv Operatyvno-rjatuval'noi' sluzhby cyvil'nogo zahystu pid chas gasinnja pozhezh. https://zakon.rada.gov.ua/laws/show/z0801-18#Text
  2. Dubinin, D. (2021). Doslidzhennja vymog do perspektyvnyh zasobiv pozhezhogasinnja tonkorozpylenoju vodoju. Problemy nadzvychajnyh sytuacij, 33, 15–29. doi: 10.52363/2524-0226-2021-33-2
  3. Dubinin, D., Lisniak, А., Shevchenko, S., Krivoruchko, I., Gaponenko, (2021). Eksperymental'ne doslidzhennja rozvytku pozhezhi v budivli. Problemy nadzvychajnyh sytuacij, 34, 110–121. doi: 10.52363/2524-0226-2021-34-8
  4. Fire Engineering. FDIC International. Retrieved from https://www.fireengineering.com
  5. NFPA 921. (2017). Guide for Fire and Explosion Investigations.
  6. NFPA 1410. (2020). Standard on Training for Initial Emergency Scene Operations.
  7. Kerber, S. (2012). Analysis of Changing Residential Fire Dynamics and Its Implications on Firefighter Operational Timeframes. Fire Technology, 48, 865–891. doi: 1007/s10694-011-0249-2
  8. Jahn, W., Rein, G., Torero, J. L. (2008). The E ect of Model Parameters on the Simulation of Fire Dynamics. Fire Safety Science, 9, 1341–1352. doi: 10.3801/IAFSS.FSS.9-1341
  9. Sun, J., Hu, L., Zhang, Y. (2013). A review on research of fire dynamics in high-rise buildings. Theoretical and Applied Mechanics Letters, 3(4), 042001. doi: 10.1063/2.1304201
  10. Lu, K., Hu, L., Tang, F., Delichatsios, M., Zhang, X., He, L. (2013). Facade Flame Heights from Enclosure Fires with Side Walls at the Opening. Procedia Engineering, 62, 202–210. doi: 10.1016/j.proeng.2013.08.056
  11. Hu, L., Tang, F., Delichatsios, M. A., Wang, Q., Lu, K., Zhang, X. (2013). Global behaviors of enclosure fire and façade flame heights in normal and reduced atmospheric pressures at two altitudes. International Journal of Heat and Mass Transfer, 56, 119–126. doi: 10.1016/j.ijheatmasstransfer.2012.09.050
  • Karlsson, B., Quintiere, J. (1999). Enclosure Fire Dynamics. CRC Press, 1, 336.
  • Karlsson, B., Quintiere, J. (2018). Enclosure Fire Dynamics. CRC Press, 2,